PERENCANAAN SISTEM PENCAHAYAAN BUATAN PADA LAPANGAN SEPAK BOLA STADION TRISANJA KABUPATEN TEGAL

Andri Rohidin, Sapto Nisworo, Deria Pravitasari

Abstract


Football is a sport that is very popular in the world, especially the people of Indonesia. Lighting on the football field is one of the most important parts of football so it does not interfere with eye vision. Lighting planning on a football field must be planned safely, comfortably and efficiently in accordance with its use and in accordance with FIFA. distribution of burdens, selection of conductors and safeguards, as well as budget plans. The results of this study are the lighting requirements from the calculation results obtained by a load of 235,200 watts. The selection of conductors for lighting the football field uses a 4 x 16mm NYY type conductor and for the main panel conductor uses a 4x50 mm NYY type conductor. The maximum voltage drop from the SDP panel to the lighting panel is 11.3 volts, and the safety system on the MDP panel uses MCCB 160A, and the recommended generator capacity is 300kVA. The results of the manual calculation of the average illumination on a football field is 1601 and from the Dialux 4.13 simulation results the average illumination is 1548 lux with an average level of 0.82 lux of light. The average illumination results between manual calculations and Dialux 4.13 simulations are slightly different due to conditions, namely differences in the calculation of utility factors and maintenance factors. The results of manual calculations and simulations of Dialux 4.13 have met FIFA standards.